Description
Designed for single-phase measurements of AC power signals. The Model 66201 includes measurement functions designed for low power applications (maximum current 2A). Included measurement data is as following :
1. Voltage : Vrms, Vpeak+, Vpeak-.
2. Current : Irms, Ipeak+, Ipeak-.
3. Power : Watts, Power Factor, Apparent Power VA, Reactive Power VAR
4. Current Crest Factor & Frequency
The Model 66202 includes a 2-shunt design to provide highly accurate readings for both low and high current measurements. In addition to the parameters measured by Model 66201, the 66202 includes Inrush current, Total Harmonic Distortion of V/I, and Energy measurements.
Technical data
• Voltage Range : 150/300/500 Vrms
• Current Range :
Model 66201 - 0.01/0.1/0.4/2 Arms
Model 66202 - 0.01/0.1/0.2/0.4/2/8/20 Arms
• Frequency Range : DC, 15Hz~10kHz